record_type,machine_key,label,value,unit,data_class,evidence_class input,workingVolumeM3,Working volume,100,m3,synthetic_deterministic_example,user-declared process input input,peakOurMolM3H,Peak volumetric oxygen uptake rate,50,mol_O2_m-3_h-1,synthetic_deterministic_example,measured or qualified process input input,oxycaloricEquivalentKjMol,Oxycaloric equivalent,440,kJ_mol-O2-1,synthetic_deterministic_example,editable literature-based assumption input,shaftPowerKw,Shaft power dissipated to broth,260,kW,synthetic_deterministic_example,measured or supplier-supported input input,auxiliaryHeatKw,Other heat input,0,kW,synthetic_deterministic_example,user-declared heat-balance input input,creditedHeatSinksKw,Credited off-gas evaporation feed and ambient heat sinks,80,kW,synthetic_deterministic_example,user-declared measured or reconciled input input,sourceFactor,Positive-source design factor,1.2,dimensionless,synthetic_deterministic_example,user-owned design input input,sinkCreditFraction,Qualified heat-sink credit fraction,1,dimensionless,synthetic_deterministic_example,user-owned design input input,brothTemperatureC,Broth temperature,30,degC,synthetic_deterministic_example,user-owned operating input input,coolantInletC,Coolant inlet temperature,10,degC,synthetic_deterministic_example,utility design input input,coolantOutletC,Coolant outlet temperature,20,degC,synthetic_deterministic_example,utility design input input,overallHeatTransferCoefficientWm2K,Overall heat-transfer coefficient,500,W_m-2_K-1,synthetic_deterministic_example,illustrative equipment assumption input,configurationFactor,Heat-transfer configuration factor,1,dimensionless,synthetic_deterministic_example,user-owned equipment assumption input,installedAreaM2,Installed wetted heat-transfer area,90,m2,synthetic_deterministic_example,equipment input input,coolantHeatCapacityKjKgK,Coolant heat capacity,4.18,kJ_kg-1_K-1,synthetic_deterministic_example,physical-property input input,coolantDensityKgM3,Coolant density,1000,kg_m-3,synthetic_deterministic_example,physical-property input input,brothHeatCapacityKjKgK,Broth heat capacity,4.18,kJ_kg-1_K-1,synthetic_deterministic_example,physical-property input input,brothDensityKgM3,Broth density,1000,kg_m-3,synthetic_deterministic_example,physical-property input input,outageHeatLoadKw,Declared loss-of-cooling heat load,871.11,kW,synthetic_deterministic_example,user-owned outage scenario input input,allowableTemperatureRiseK,Illustrative temperature-rise interval,2,K,synthetic_deterministic_example,user-owned screening input result,metabolicHeatKw,Peak metabolic heat,611.11,kW,synthetic_deterministic_example,calculated result,nominalNetHeatLoadKw,Nominal net heat load,791.11,kW,synthetic_deterministic_example,calculated result,designCoolingDutyKw,Design cooling duty,965.33,kW,synthetic_deterministic_example,calculated result,logMeanTemperatureDifferenceK,Log-mean temperature difference,14.43,K,synthetic_deterministic_example,calculated result,requiredAreaM2,Required heat-transfer area,133.82,m2,synthetic_deterministic_example,calculated result,installedCoolingCapacityKw,Installed cooling capacity,649.21,kW,synthetic_deterministic_example,calculated result,capacityShortfallKw,Cooling-capacity shortfall,316.12,kW,synthetic_deterministic_example,calculated result,additionalAreaRequiredM2,Additional heat-transfer area,43.82,m2,synthetic_deterministic_example,calculated result,coolantMassFlowKgS,Required coolant mass flow,23.09,kg_s-1,synthetic_deterministic_example,calculated result,coolantVolumeFlowM3H,Required coolant volume flow,83.14,m3_h-1,synthetic_deterministic_example,calculated result,outageTemperatureRiseKH,Initial loss-of-cooling temperature rise,7.50,K_h-1,synthetic_deterministic_example,calculated result,outageTimeToLimitMin,Time to illustrative temperature rise,15.99,min,synthetic_deterministic_example,calculated