scenario,batch_volume_m3,pressure_mpa,passes,available_cycle_window_h,non_processing_time_h,rated_flow_per_unit_m3_h,flow_derating,duty_units,process_time_h,cycle_time_h,shaft_power_total_kw,motor_power_each_with_margin_kw,specific_energy_kj_kg,no_cooling_delta_t_k,cooler_design_kw,coolant_flow_m3_h,calibrated_disruption_fraction,recovered_suspension_kg,pass_loss_kg,schedule_pass,temperature_control_required,product_target_pass,data_class,source_or_assumption,formula_ids lower_pressure,12,60,2,4,1,5,0.8,2,3,4,185.1852,106.4815,161.8123,26.8857,138,19.8086,0.7000,12236.709,123.291,true,true,false,synthetic_assumption_and_model_output,"Synthetic engineering scenario; not measured plant or customer data",HPH-01|HPH-02|HPH-03|HPH-04|HPH-05|HPH-06 base_two_units,12,80,2,4,1,5,0.8,2,3,4,246.9136,141.9753,215.7497,35.8476,184,26.4115,0.7707,12236.709,123.291,true,true,false,synthetic_assumption_and_model_output,"Synthetic calibration is 70% at 60 MPa and two passes with pressure exponent 0.70; not transferable",HPH-01|HPH-02|HPH-03|HPH-04|HPH-05|HPH-06 negative_one_unit,12,80,2,4,1,5,0.8,1,6,7,123.4568,141.9753,215.7497,35.8476,92,13.2057,0.7707,12236.709,123.291,false,true,false,synthetic_assumption_and_model_output,"One-duty-unit negative schedule case; no supplier model selected",HPH-01|HPH-02|HPH-03|HPH-04|HPH-05|HPH-06 three_pass_two_units,12,80,3,4,1,5,0.8,2,4.5,5.5,246.9136,141.9753,323.6246,53.7715,184,26.4115,0.8902,12175.5255,184.4745,false,true,true,synthetic_assumption_and_model_output,"Extra-pass case passes fitted product screen but misses the synthetic cycle window",HPH-01|HPH-02|HPH-03|HPH-04|HPH-05|HPH-06 three_pass_three_units,12,80,3,4,1,5,0.8,3,3,4,370.3704,141.9753,323.6246,53.7715,276,39.6172,0.8902,12175.5255,184.4745,true,true,true,synthetic_assumption_and_model_output,"Parallel-duty alternative; flow split cooling headers and qualification are outside this screen",HPH-01|HPH-02|HPH-03|HPH-04|HPH-05|HPH-06